The BF mechanical agitation flotation machine mixes pulp and air within a single tank. It generates fine bubbles through a rotor-stator mechanism, drawing air without an external blower. This self-aeration reduces auxiliary equipment and simplifies installation.

01Model
02Effective Volume (m3)
03Processing Capacity (m3/min)
04Max Air Intake (m3/m2.min)
05Motor Power (kW)
06Dimensions (mm)
07Single Tank Weight (kg)

Technical parameters

The machine sits in the flotation circuit, typically after grinding and classification. It handles rougher, scavenger, and cleaner duties. A bank of cells is arranged in series, with froth overflowing to launder and tailings moving downstream.

The table spans small laboratory-scale cells to large production units. Effective volume and processing capacity increase with model size. Motor power and air intake scale accordingly, while tank dimensions grow to accommodate higher throughput. Selection hinges on required retention time and target production rate.

BF Mechanical Agitation Flotation Machine technical parameters, 16 models
ModelEffective Volume (m3)Processing Capacity (m3/min)Max Air Intake (m3/m2.min)Motor Power (kW)Dimensions (mm)Single Tank Weight (kg)
AgitationScraper
BF-0.050.050.01-0.0510.550.18390×390×340105
BF-0.150.150.06-0.1611.50.55550×550×600240
BF-0.250.250.12-0.2811.50.55600×600×700340
BF-0.370.370.2-0.411.50.55700×700×750405
BF-0.70.70.3-0.7131.1900×900×860640
BF-1.21.20.6-1.315.51.11100×1100×11001370
BF-221.5-2.51111.51600×1600×11502150
BF-2.82.81.5-3.11111.51700×1600×11502230
BF-442-41151.51850×2050×12002790
BF-663-61302.22200×2286×12633620
BF-884-81302.22200×2900×14004500
BF-10105-101302.22200×2900×17004750
BF-16165-161451.52850×3800×17006940
BF-20205-201551.52850×3800×20009800
BF-24245-241551.53150×4150×200010150
BF Mechanical Agitation Flotation Machine, continued (25 rows)
ModelEffective Volume (m3)Processing Capacity (m3/min)Max Air Intake (m3/m2.min)Blower Air Pressure (Kpa)Motor Power (kW)Dimensions (mm)Single Tank Weight (kg)
AgitationScraper
XCF-110.2-12≥12.65.50.751000×1000×11001154
KYF-14903
XCF-220.4-22≥14.77.51.11300×1300×12301659
KYF-25.51419
XCF-441.2-42≥19.8151.51800×1800×15002170
KYF-4111920
XCF-883-82≥21.6221.52200×2200×19504380
KYF-8153885
XCF-10104-102≥21.6301.52370×2370×21004325
KYF-10224010
XCF-16164-162≥25.5371.52800×2800×24006205
KYF-16305705
XCF-20204-202≥27451.52920×2920×27307586
KYF-20376667
XCF-24244-242≥30.4551.53100×3100×29009935
KYF-24378265
XCF-30307-302≥31.6551.53500×3500×302512005
KYF-304510455
XCF-383810-382≥34.3751.53600×3600×340013200
KYF-385511566
XCF-404010-402≥35751.53800×3800×340013750
KYF-405512116
XCF-505010-402≥42902.24200×4200×360014500
KYF-507513800
BF Mechanical Agitation Flotation Machine, continued (6 rows)
ModelTank Diameter (mm)Tank Height (mm)Effective Volume ( m3 )Processing Capacity ( m^3/min )Maximum Air Inflation ( m^3/m^2.min )Blower Air Pressure (Kpa)Motor Power (kW)
KYF-5046003500505-251.5≥ 4275
KYF-70520042007020-501.5≥ 45110
KYF-1005800456010020-601.5≥ 52185
KYF-1306200480013020-601.5≥ 55220
KYF-1606800550016020-601.5≥ 60250
KYF-2007500560020020-1001.5≥ 65280
BF Mechanical Agitation Flotation Machine, continued (9 rows)
ModelEffective Volume (m3)Feed Particle Size (mm)Processing Capacity (m3/min)Blower Air Pressure (Kpa)Maximum Air Inflation (m3/m2.min)Motor Power (kW)Dimensions (mm)Single Tank Weight (kg)
AgitationScraper
CLF-2Suction Tank2< 11-2≥ 1527.51.51200×1600×12501591
Direct Current Tank5.51481
CLF-4Suction Tank4< 11-4≥ 19.82151.51600×2100×15003202
Direct Current Tank112955
CLF-8Suction Tank8< 11-8≥ 21.62221.52500×1900×19304690
Direct Current Tank154360
CLF-16Suction Tank16< 15-16≥ 252451.52500×3200×24006975
Direct Current Tank376350
Parameter boundary

Standard-model catalogue figures. Actual capacity, power draw and wear life shift with ore properties, feed gradation and circuit conditions. Use them to shortlist, then confirm the duty by testwork, flowsheet calculation and a written confirmation from the manufacturer.

What decides the selection

Before fixing a model, confirm the ore’s flotation kinetics, pulp density, and desired residence time. The required number of cells and bank configuration follow from laboratory or pilot testing. Matching the cell volume to the plant’s throughput avoids over- or under-sizing, which can affect both capital cost and operating expense.

  • Ore floatability
  • Particle size
  • Pulp density
  • Cell volume
  • Aeration rate and agitation intensity
  • Number of circuit stages
  • Froth depth control
  • Specific energy consumption and wear parts

All flotation equipment

Other flotation machines

30+
years in mining equipment
1,000+
equipment models
70+
ore types processed
100+
countries reached

ISO 9001 / ISO 14001 / ISO 45001 / ISO 9712 / CE / CSA W47.1 / CNAS accredited laboratory

Send the duty, get a sized proposal

Tell us the ore, the throughput and the target product. Our process engineers come back with a flowsheet position, a model shortlist and the testwork we would need to confirm it.