Dust Collection Equipment
CCJ/A Type Wet Dust Remover Assembly
The CCJ/A Type Wet Dust Remover Assembly collects airborne dust from crushing, screening and conveying operations in mineral processing plants. It uses water to capture particles through inertial impact and scrubbing, then discharges clean air. The unit installs downstream of dust sources and upstream of the exhaust stack.
Technical parameters
Suited to sticky or abrasive dusts that blind fabric filters, it reduces maintenance in wet environments. Xinhai supplies it with matched blowers and pumps for simpler integration.
The parameter table covers the CCJ/A series, from smaller units for isolated sources to large assemblies for centralised systems. Key variables include equipment resistance, purification efficiency and ventilator type. Larger models accommodate higher gas flow rates with proportionally greater resistance; efficiency stays consistent across the range. The model code (e.g., XW1/1) identifies the ventilator and assembly configuration.
| Model/Associated Data | CCJ/A-5 | CCJ/A-7 | CCJ/A-10 | CCJ/A-14 | CCJ/A-20 | CCJ/A-30 | CCJ/A-40 | CCJ/A-60 | ||
|---|---|---|---|---|---|---|---|---|---|---|
| Dust Collector | Air Volume ( m^3/h ) | 5000 | 7000 | 10000 | 14000 | 20000 | 30000 | 40000 | 60000 | |
| Equipment Resistance (Pa) | 1000-1200 | |||||||||
| Purification Efficiency % | >97 | |||||||||
| Ventilator | 4-72-II Type Ventilator | Model | 4A | 4.5A | 5A | 6C | 8C | 8C | 10C | 12C |
| Speed (r/min) | 2900 | 2900 | 2900 | 2240 | 1600 | 1800 | 1250 | 1120 | ||
| Air Volume ( m^3/h ) | 4020-7420 | 5730-10580 | 7950-14720 | 11900-17100 | 17920-31000 | 20100-34800 | 34800-50150 | 53800-77500 | ||
| Total Pressure (Pa) | 2040-1340 | 2580-1700 | 3240-2240 | 2720-2290 | 2520-1880 | 3180-2410 | 3180-2410 | 2770-2190 | ||
| Motor | Model | Y132S1-2 | Y132S2-2 | Y160M2-2 | Y180M-4 | Y180M-2 | Y200L2-2 | Y225M-4 | Y280S-4 | |
| Power (kW) | 5.5 | 7.5 | 15 | 18.5 | 22 | 37 | 55 | 75 | ||
| Water Consumption | Evaporation (kg/h) | 17.5 | 24.5 | 35 | 49 | 75 | 105 | 140 | 210 | |
| Overflow (kg/h) | 150 | 210 | 300 | 420 | 600 | 900 | 1200 | 1800 | ||
| Bottom Flow (kg/h) | 425 | 602 | 860 | 1200 | 1700 | 2550 | 3400 | 5100 | ||
| Flushing Volume ( m3 ) | 0.48 | 0.66 | 1.04 | 1.2 | 1.7 | 2.5 | 3.4 | 5 | ||
| Unit Weight (kg) | 791 | 956 | 1196 | 2426 | 3277 | 3955 | 4989 | 6765 | ||
| Remarks | The power of the solenoid valve used in the automatic water level control system is 80 VA. |
| Model | XW1/1 | XW1/2 | XW1/3 | XW1/4 | XW1/5 | XW1/6 |
|---|---|---|---|---|---|---|
| Power (kW) | 1.1 | 2 | 3 | 4 | 7.5 | 11 |
| Voltage (V) | 380 | |||||
| Input Line System | Three-Phase Five-Wire | |||||
| Maximum Spray Flow Rate (t/h) | 0.3 | 0.6 | 0.9 | 1.25 | 2 | 4 |
| Inlet Size | 0.5"/DN15 | 0.5"/DN15 | 0.5"/DN15 | 1"/DN25 | 1.5"/DN40 | 2"/DN50 |
| Outlet Size | 1/8"-1 | 1/8"-1 | 1/8"-2 | 1/8"-3 | 1/4"-2 | 1/2"-2 |
| Dimensions (mm) | 1400×700×1600 | |||||
| Water Supply | Sub-Water Tank Automatic Control | |||||
| Signal | 4-20mA Current Signal | |||||
| Control System | PLC Programmable Control System |
| Model/Specifications | ECMC-11 | ECMC-15 | ECMC-20 | ECMC-30 | ECMC-40 | |
|---|---|---|---|---|---|---|
| ECMC Series Top Dust Remover | Air Volume ( m^3/h ) | 720-990 | 1040-1420 | 1500-2100 | 2100-2900 | 2800-3800 |
| Fan Power (kW) | 2.2 | 2.2 | 4 | 4 | 5.5 | |
| Filter Bag Specification (mm) | φ140x1000 | φ140x1000 | φ140x1500 | φ140x1500 | φ140x2000 | |
| Number of Filter Bags | 25 | 36 | 36 | 49 | 49 | |
| Filtration Area ( m2 ) | 11 | 15.8 | 23.7 | 32.3 | 43.1 | |
| Pulse Valve Specification | 1.0" | |||||
| Number of Pulse Valves | 5 | 6 | 6 | 7 | 7 | |
| Filter Bag Material | Coated Polyester Fiber | |||||
| Cleaning Method | Pulse Cleaning | |||||
| Equipment Dimensions (mm) | Length (mm) | 1100 | 1300 | 1300 | 1470 | 1470 |
| Width (mm) | 1100 | 1300 | 1300 | 1470 | 1470 | |
| Height (mm) | 1400 | 1400 | 1900 | 1900 | 2400 | |
| Purification Efficiency % | >99.5 |
| Model/Specifications | ETMC I-8 | ETMC I-12 | ETMC I-16 | ETMC II-24 | ETMC III-36 | ETMC IV-48 | ETMC IV-60 | ETMC IV-72 | |
|---|---|---|---|---|---|---|---|---|---|
| Filter Cartridge Main Unit Specifications | Air Volume (m3/h) | 2250-4500 | 3380-6760 | 4500-9000 | 6760-13520 | 10150-20300 | 13530-27060 | 16920-33840 | 20300-40600 |
| Fan Power (kW) | 5.5 | 7.5 | 11 | 15 | 22 | 30 | 37 | 45 | |
| Number of Filter Cartridges | 8 | 12 | 16 | 24 | 36 | 48 | 60 | 72 | |
| Filtration Area (m2) | 75.2 | 112.8 | 150.4 | 225.6 | 338.4 | 451.2 | 564 | 676.8 | |
| Pulse Valve Specification | 1.0" | ||||||||
| Number of Pulse Valves | 4 | 6 | 8 | 12 | 18 | 24 | 30 | 36 | |
| Filter Bag Materia | Coated Polyester Fiber | ||||||||
| Cleaning Method | Pulse Cleaning | ||||||||
| Equipment Dimensions (mm) | Length (mm) | 1100 | 1100 | 1100 | 2200 | 3300 | 4400 | 5500 | 6600 |
| Width (mm) | 1860 | 1860 | 1860 | 1860 | 1860 | 1860 | 1860 | 1860 | |
| Height (mm) | 2900 | 3400 | 3900 | 3400 | 3400 | 3400 | 3400 | 3400 | |
| Purification Efficiency % | >99.5 |
Standard-model catalogue figures. Actual capacity, power draw and wear life shift with ore properties, feed gradation and circuit conditions. Use them to shortlist, then confirm the duty by testwork, flowsheet calculation and a written confirmation from the manufacturer.
What decides the selection
Define the total airflow required and the dust loading of each airstream to be extracted. Confirm the dust characteristics: particle size distribution, moisture content and whether the material is sticky or abrasive. Specify the available water quality and disposal route for the slurry. Determine the layout constraints that dictate duct positions and the space available for the assembly, including the ventilator footprint.
- Air volume
- Inlet dust concentration
- Particle size
- Temperature and humidity
- Explosibility
- Emission limit
- Filtration velocity and pressure drop
- Cleaning method
- Water availability
Other dust collection machines
- Chamber Jetting Bag Dust Remover33 models
- High-Efficiency Wet Dust Remover8 models
ISO 9001 / ISO 14001 / ISO 45001 / ISO 9712 / CE / CSA W47.1 / CNAS accredited laboratory
Send the duty, get a sized proposal